Sign In | Join Free | My hardware-wholesale.com |
|
Brand Name : ESTEL
Model Number : GPE4860C
Certification : ISO9001, CE, 3C, FCC, TLC
Place of Origin : Shenzhen, China (Mainland)
MOQ : 1
Price : negotiation
Payment Terms : L/C, D/A, D/P, , T/T, Western Union
Supply Ability : 10,000 sets per month
Delivery Time : 7-10 working days
Packaging Details : carton/wooden case
Installation Mode : 19” rack
Output Power : 3200W
Input Voltage : AC220V
Output Current : 60A
Power Factor : 0.98
Input Frequency : 45~65Hz
Application : outdoor telecom cabinet
Outdoor Data Cabinet Telecom Power Systems Low Power Consumption GPE4860C
Quick Details:
Place of Origin: Shenzhen, China (Mainland) | Input Voltage: AC220V |
Brand Name: ESTEL | Output Voltage: DC48V |
Model Number: GPE4860C | Output Power: 3200W |
Product Name: Telecom Power System | Input Frequency 45~65Hz |
Certification: ISO9001, CE, 3C, FCC, TLC | Output Current: 60A |
Installation Mode: 19” rack | Power Factor: 0.98 |
Application: outdoor UPS cabinet | Components: 2×30A rectifier module, 1×monitoring module, power distribution |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 set |
Price: | negotiation |
Payment Terms: | L/C, D/A, D/P, , T/T, Western Union |
Supply Ability: | 10,000 sets per month |
Delivery Time: | 7-10 working days |
Packaging Details: | carton/wooden case |
The system consists of distribution unit, rectifier module (up to 2 sets) and 1 monitoring module. The configuration is optional, as following table:
Configuration | Rectifier Module | Monitoring Module | Distribution |
Standard | GPR4830A/B | GPM48M | DC output: 40A×1 (Load); Battery output: 40A×1 (Battery) |
Under normal conditions, every parameter of rectifier modules and distribution unit are all under control of the monitoring module, operating according to the pre-set parameter or user’s commands. If AC mains fault, the system will be powered by the battery. With the battery discharge, the terminal voltage of the battery starts to descend. When the battery voltage is under 42V±0.5V, the monitoring module reports battery under voltage alarm signal and cuts off the load output, then the power system stops working. When the external AC mains recovers, the system will resume to the normal work state. (All above monitoring data are system default values that users can reset).
Except for battery over-discharge protection, battery or load over-temperature protection is prohibitive under default, users can send command to activate or inactivate according to the demanding. When the operating temperature is 55°C or more, power de-rating will be employed by system.
Input | |||||
Parameter | Min. | Typical | Max. | Unit | Remark |
Input voltage range | 90 | 220 | 285 | Vac | Nominal operating voltage: 100V-240V |
Input frequency | 45 | 50 | 65 | Hz | |
Inrush current | 50 | A | Cold start @ 25°C, 285 Vac input Tested at full load | ||
Power factor | 0.98 |
Output | |||||
Parameter | Min. | Typical | Max. | Unit | Remark |
Output voltage rating | -53.5 | Vdc | |||
Output voltage range | -43.2 | -53.5 | -57.6 | Vdc | |
Output current range | 0 | 60 | A | 176~285VAC | |
Ripple (Vp-p) | 200 | mv | After 1-hour operation at low temperature, apply 0.1uF film capacitor and 10uF HF electrolyte capacitor, oscilloscope band width of 20MHz, with 20CM twisted pair. | ||
Output efficiency | 90 | % | 220Vac input, rated output | ||
82 | % | 110Vac input, 15A output | |||
Regulation | ±2 | % | |||
Load regulation | ±2 | % | |||
Line regulation | ±1 | % | |||
Output power | 3200 | W | 176-285V Input | ||
1200 | W | 90-175V Input |
Insulation rating | ||
Parameter | Requirement | Remark |
Input - output | 3500Vdc/10mA//1min | No flashover and breakdown, with discharge tube removed. |
Input-chassis | 3500Vdc/10mA//1min | |
Output - chassis | 750Vdc/10mA//1min | |
Leakage current | ≤3.5mA | |
Insulation resistance | At normal atmospheric pressure, relative humidity: 90%, testing voltage: 500vdc, insulation of input-output, input-ground, output-ground shall not be less than 10MΩ |
Ambient requirements | |||||
Parameters | Min. | Typical | Max. | Unit | Remark |
Nominal operating temp | -15 | 25 | +55 | °C | |
Operating temp | -33 | +55 | °C | Start up with full load at -40°C, normal operation, with partial degradation of performance permissible. For temperature between 55°C and 65°C, output with derating to 80% | |
Storage tempStorage temperature | -40 | +70 | °C | ||
Relative humidity | 5 | 95 | % | Long-term operation, no condensing | |
Atmospheric pressure | 70 | 106 | KPa | ||
Altitude | 0 | 4000 | m | ||
Cooling method | Forced cooling, front-in & rear-out, the fan is located inside the front panel, with speed programmable by the temperature. | ||||
Ingress protection | The unit can operate when the diameter of dust particle is more than 5µm, with density ≤3*104 /m3. The dust shall not be conducting, electromagnetic or corrosive. |
Mechanical specifications | |
Dimensions (Overall) | 442mm×250mm×43.6mm |
Weight(kg) (Overall) | ≤7Kg(including modules) |
Chassis connects with external electric through system interface board. As shown in figure below:
1. Bracket 2. AC input socket with three-core
3. Rectifier module 4.Monitoring module
5. Signal interface 6. Output connectors
5. Application
(1) Small scale program controlled exchanger
(2) Access network
(3) Transmission equipment
(4) Mobile communication
(5) Satellite communication ground station
(6) Microwave communication
(1) Adoption of active power factor compensation technology with factor >0.98
(2) Wide operating range of AC input voltage: 90~285Vac
(3) Operating temperature range:-33°C~+55°C
(4) Zero current/voltage switching tech with high efficiency ≥90%
(5) Perfect battery management, battery temperature compensation, LVLD and LVBD protection, battery capacity test
(6) Hot-swappable
(7) Input over/under voltage protection
(8) Output over voltage protection
(9) Output over current protection
(10) Output short circuit protection
(11) Auto current sharing, parallel operation
(12) Embedded mounted
(13) Multiple communication ports, easy for networking and remote management
7. Packing and Shipping
Our Delivery Agent
The goods can be shipped by sea, by air, by courier, by land, by train, etc.
Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.
8. Our Contact Information
Mobile Phone: 0086-13752765943
Telephone: 0086-0755 66600941
Email: info@estel.com.cn
lxf.estel@hotmail.com
Skype: fiona.liang10
9. Our Partner
![]() |
Outdoor Data Cabinet Telecom Rectifier System Images |